  Close Menu

Approved Technologies

The department maintains the list below of TNI that have been listed for use in Indiana. Where applicable, a link for each technology is provided to the department standards for that technology. These standards are the basis for plan review, construction approvals, training, design and installation, and operation and maintenance (O&M), if applicable.

Information is grouped under four technology categories: "Components," "Secondary Treatment Units," "Soil Absorption Fields," and "Pretreatment Devices,"

Each listing includes the following:

  • Manufacturer information (listed alphabetically by manufacturer's name);
  • The name of the technology;
  • Its status: general approval, conditional approval, and project-by-project approval;
  • Date of approval;
  • Description of the technology;
  • Brief comments regarding the approval; and

A link to the standards  that are the basis for plan review, construction approvals, training, design and installation, and operation and maintenance (O&M), when applicable.

Components

Onsite system components are evaluated on a case-by-case basis. Components may include distribution boxes, distribution devices, siphons, pressure manifolds, etc.

Fluid Dynamic Siphons, Inc.
P.O. Box 88219
Steamboat Springs, CO 80488-2019

Web site: http://www.siphons.com/

Technology:Siphons.
Status:Project-by-project approval.
Description:Automatic dosing siphons for small flood dose systems, typically used in place of a pump on sites where electricity is not available.

SeptiSurge
6328 East Collins Lane
Bloomington, IN 47408

Mr. Neil Zook
Email: neilzook@gmail.com
Web site: www.septisurge.com

Technology:Model 3A and Model 3B
Status:Approved
Date:5/20/2013
Description:MOLDED distribution box with 6 or 8 ports. Equally distributes flow to each port.
CommentsSEE APPROVAL LETTER FOR ALL CONDITIONS: Subsurface gravity trench systems only; must be installed according to installation instructions.
Link to Approval LetterApproval Letter 

Zoeller Company
3649 Cane Run Rd
Louisville, KY 40211-1961

Mr. Adrian France
Phone: (502) 778-2731
Fax: (502) 774-3624
Email: adrianf@zoeller.com
Web site: www.zoeller.com

Technology:Tru-Flow Splitter
Status:Approved
Date:5/22/2006
Description:D-box of molded polypropylene with two parts: housing (basin/cover) and diverter. Bubble level allows for post installation adjustments to equalize flow to five lines.
CommentsSEE STANDARD FOR ALL CONDITIONS: Subsurface gravity trench systems only; must be installed according to Zoeller installation requirements.
Link to StandardsStandards

Secondary Treatment Systems

The use of secondary treatment systems in Indiana must comply with the requirements in the Indiana Standards for Secondary Treatment Systems. Secondary treatment systems are reviewed by the department after submittal by a manufacturer or system integrator (SI).

To be listed, the manufacturer of a secondary treatment system must have on file with the department an application and documentation for review against the requirements of Indiana Standards for Secondary Treatment Systems. Such listing will have the status either “Project-by-project approval” or “Approved” A status of “Project-by-project approval” means that the department may approve the use of the technology on a case by case basis for individual projects under the parameters of Indiana Standards for Secondary Treatment Systems. But until a general approval is issued, each individual project must be reviewed by the department. When the department has finished a satisfactory review of the technology, the status will be changed from “project-by-project approval” to “Approved.” At that time, local health departments may issue permits for the use of that technology, provided such approvals meet all of the requirements of the standards for that technology as well as all of the requirements of 410 IAC 6-8.3.

For the repair, remediation or replacement of an existing residential onsite soil absorption field, the use of a secondary treatment unit must comply with the applicable requirements of 410 IAC 6-8.3.

BioMicrobics
16002 West 110th Street
Lenexa, KS 66219 USA
Website: http://www.biomicrobics.com/

Sheryl Ervin, P.G.
Manager, Regulatory Affairs & Special Projects
Phone: (913)422-0707
Fax: (913)422-0808

Technology:MicroFAST 0.5, 500 gpd
MicroFAST 0.75, 750 gpd
MicroFAST 0.90, 900 gpd
MicroFAST 1.50, 1500 gpd
Status:Approved
Description:A polyethylene aeration insert into a concrete tank using a fixed film extended aeration, activated sludge process.
Comments:SEE APPROVAL LETTER FOR ALL CONDITIONS
Link to Approvals:

Approval Letter
BioMicrobics Tank Suppliers

Technology:HighStrengthFAST 1.0, 1000 gpd
HighStrengthFAST 1.5, 1500 gpd
HighStrengthFAST 3.0, 3000 gpd
HighStrengthFAST 4.5, 4500 gpd
HighStrengthFAST 9.0, 9000 gpd
Status:Approved; but only for individual projects that are reviewed by IDOH
Description:A polyethylene aeration insert into a concrete tank using a fixed film extended aeration, activated sludge process.
Comments:SEE APPROVAL LETTER FOR ALL CONDITIONS
Link to Approvals:

Approval Letter
BioMicrobotics Tank Suppliers

Technology:RetroFAST 0.15, 150 gpd
RetroFAST 0.25, 250 gpd
RetroFAST 0.375, 375 gpd
Status:Project by Project approval only for projects reviewed by IDOH
Description:A polyethylene aeration insert into a concrete tank using a fixed film extended aeration, activated sludge process.

E-Z Treat, Inc.
PO Box 176
Haymarket, VA 20168 USA
Website: www.eztreat.net

Mike Stidham
Vice President
Phone: (703)408-2916

Technology:

E-Z Treat RSF #600, 600 gpd
E-Z Treat RSF #750, 750 gpd

E-Z Treat RSF #1200, 1200 gpd

Status:Approved
Description:A polyethylene (600 and 750) or fiberglass (1200) pod operates as a fixed media, packed bed recirculating filter system. Treatment using a recirculating media filtration systems is generally an aerobic process and reaeration of the media, which occurs during the resting (non-dosing) periods is essential for proper treatment.
Comments:SEE APPROVAL LETTER FOR ALL CONDITIONS
Link to Approvals:

Approval Letter
Design, Installation and Operation & Maintenance Manual, December 2020

Approved System Design Directory

Technology:

E-Z Treat RSF #600, 600 gpd
E-Z Treat RSF #750, 750 gpd

E-Z Treat RSF #1200, 1200 gpd

E-Z Treat RSF #3L, 2426 gpd

E-Z Treat RSF #4L, 3273 gpd

E-Z Treat RSF #5L, 4119 gpd

E-Z Treat RSF #6L, 5000 gpd
Status:

High Strength Waste Treatment Approved; but only for individual projects that are reviewed by IDOH

Description:

A polyethylene (600 & 750) or fiberglass (1200, 3L, 4L, 5L & 6L) pod operates as a fixed media, packed bed recirculating filter system. Treatment using a recirculating media filtration system is generally an aerobic process and reaeration of the media, which occurs during the resting (non-dosing) periods is essential for proper treatment.

Comments:SEE APPROVAL LETTER FOR ALL CONDITIONS Including BOD ratings and design calculations requirement
Link to Approvals:

Approval Letter
Design, Installation and Operation & Maintenance Manual, December 2020


Fuji Clean USA, LLC

41-2 Greenwood Road

Brunswick, ME  04011

Website: www.fujicleanusa.com

Scott Samuelson
Managing Director
Phone: 207-406-2927

Email: Scott@FujiCleanUSA.com

Technology:CE Series 5, 450 gpd
CE Series 7, 630 gpd
CE Series 10, 900 gpd
CEN Series 5, 450 gpd
CEN Series 7, 630 gpd
CEN Series 10, 900 gpd
Status:Approved
Description:Fiber-reinforced plastic tank using controlled, recirculating, circuitous flow train through   anaerobic and  aerobic cells for both biological digestion and mechanical filtration of the   wastewater.
Comments:SEE APPROVAL LETTER FOR ALL CONDITIONS

AND APPROVED MANUFACTURER MANUALS

Link to Approvals:

Approval Letter

Design Manual

Installation Manual

Operation and Maintenance Manual

Owner’s Manual


Hydro-Action
AK Industries
Hydro-Action Mfg.
P.O. Box 640
Plymouth, IN 46563
Website: www.hydro-action.com

Steve Davis
Approvals Manager
Phone: (574)936-2542 x221
Fax: (574)936-2298
Email: steved@akindustries.com

Technology:Hydro-Action AP500, 500 gpd
Hydro-Action AP600, 600 gpd
Hydro-Action AP750, 750 gpd
Hydro-Action AP1000, 1000 gpd
Hydro-Action AP1500, 1500 gpd
Status:Approved
Description:Fiberglass tanks using extended aeration, activated sludge process.
Comments:SEE APPROVAL LETTER FOR ALL CONDITIONS
Link to Approvals:Approval Letter

Jet, Inc.
750 Alpha Drive
Cleveland, OH 44143
Website: http://www.jetincorp.com/

Chris Mandich
National Sales Representative
Phone: (216) 538-8805
Email: cmandich@jetincorp.com

Technology:J-500, 500 gpd
J-750, 750 gpd
J-1000, 1000 gpd
J-1250, 1250 gpd
J-1500, 1500 gpd
J-500-PLT, 500 gpd
J-800-PLT, 800 gpd
Status:Approved
Description:Concrete or plastic tanks using a fixed film extended aeration, activated sludge process.
Comments:SEE APPROVAL LETTER FOR ALL CONDITIONS
Link to Approvals:Approval Letter

Norweco
220 Republic Street
Norwalk, OH 44857
Website: www.norweco.com

Scott Hetrick
Sales Manager
Phone: (419)668-4471
Email: shetrick@norweco.com

Technology:

Singulair Model 960-500, 500 gpd
Singulair Model 960-600, 600 gpd
Singulair Model 960-750, 750 gpd
Singulair Model 960- 1,000, 1,000 gpd
Singulair Model 960-1,250, 1,250 gpd
Singulair Model 960-1,500, 1,500 gpd
Singulair Model 960 LP-500, 500 gpd
Singulair Model 960 LP-1000, 1,000 gpd
Singulair Green 960-500, 500 gpd
Singulair Green 960-600, 600 gpd
Hydro-Kinetic 600 FEU, 600 gpd

Status:Approved
Date:Singulair & Singulair Green - 07/31/2012
Hydro-Kinetic 600 FEU – 02/21/14
Description:Concrete or polyethylene tanks using extended aeration, activated sludge process.
Comments:SEE APPROVAL LETTERS FOR ALL CONDITIONS
Link to Approvals:Singular Green Approval Letter
Singular Approval Letter
Hydro-Kinetic 600 FEU Approval Letter

Quanics, Inc.
244 Old LaGrange Road
P.O. Box 1520
Crestwood, KY 40014
Website: www.quanics.net

Kevin Sherman
Phone: 502) 992-8215
Email: osmc2001@yahoo.com

Technology:AeroCell
BioCoir
Status:Project-by-project approval
Date:07/31/2012
Description:Aerocell is a recirculating treatment system using open cell foam media. BioCoir is a recirculating treatment system using recycled husks of coconuts. Both use fiberglass tanks.

SludgeHammer Group, Ltd.
4772  US Hwy 131, Bldg, D
Petoskey, MI 49770
Website: www.sludgehammer.net

William Stoddard
President
Phone: (231) 348-5866

Technology:S-400, 400 gpd
S-600, 600 gpd
S-800, 800 gpd
S-1000, 1000 gpd
Status:Approved
Description:

Concete tanks using extended aeration, fixed-film process with bacterial inoculation to achieve treatment.

Comments:SEE APPROVAL LETTER FOR ALL CONDITIONS
Link to Approvals:

Approval Letter


Zoeller Company
3649 Cane Run Rd
Louisville, KY 40211-1961

Mr. Adrian France
Phone: (502) 778-2731
Fax: (502) 774-3624
Email: adrianf@zoeller.com
Web site: www.zoeller.com

Technology:Recirculating Gravel Filter.
Status:Project-by-project approval
Description:Recirculating gravel filter with a bed of gravel to treat effluent with organisms that live on the media (80% of effluent is recirculated for additional treatment). Numerous sizes are available to accommodate a range of loading and site requirements.
Technology:Z-Cell Wetland
Status:Project-by-project approval.
Description:The Z-Cell is a constructed wetland that manages the inflow of effluent using time dosing and uniform application to the bottom of the treatment cell. Effluent moves vertically through the horizontally-oriented plant root zone to provide treatment.

Soil Absorption Fields

The department has general standards for some soil absorption field TNI. Other technologies are evaluated on a case-by-case basis. The use of these technologies in Indiana must comply with the requirements in the standards or approval. Soil absorption field technology for which the department has established general standards include:

Advanced Drainage Systems, Inc.
3300 Riverside Drive, P.O. Box 21307
Columbus, OH 43221


Phone: (800) 821-6710
Web site: http://www.ads-pipe.com/

Technology:Gravelless Pipe Technology
Status:Approved
Date:11/28/1988
Description:8" & 10" corrugated polyethylene plastic pipe with 3/8" or 1/2" diameter holes located 120 degrees from the top centerline and wrapped with Cariff non-woven polyester geotextile fabric.
CommentsSEE APPROVAL LETTER FOR ALL CONDITIONS: install in gravity trenches only; SAF size: 1 Lf of 10" dia. pipe in great. or eq. to 20" trench corr. to 1 Lf of 3' wide trench; 1 Lf of 8" dia. pipe in great. or eq. to 16" trench corr. to 1 Lf of 2' wide trench.
Link to ApprovalApproval Letter

Baughman Tile Company
8516 Township Road
Paulding, OH 45879

Lorie Thornell

Technology:Gravelless Pipe Technology
Status:Approved
Date:8/6/2002
Description:8" & 10" corrugated polyethylene plastic pipe with 3/8" or 1/2" diameter holes located 120 degrees from the top centerline and wrapped with Cariff non-woven polyester geotextile fabric.
CommentsSEE APPROVAL LETTER FOR ALL CONDITIONS: install in gravity trenches only; SAF size: 1 Lf of 10" dia. pipe in great. or eq. to 20" trench corr. to 1 Lf of 3' wide trench; 1 Lf of 8" dia. pipe in great. or eq. to 16" trench corr. to 1 Lf of 2' wide trench.
Link to ApprovalApproval Letter

Eljen Corporation
125 McKee Street
East Hartford, CT 06108

Mr. Jim King
Phone: (800) 444-1359
Fax: (860) 610-0427
Email: jking@eljen.com
Web site: http://www.eljen.com/

Technology:GSF (Geotextile Sand Filter) modules (A42 and B43)
Status:Approved
Date:03/25/2014
Description:Cuspated plastic core units [B43 measuring 48" x 36" x 7" (L x W x H) and A42 measuring 48" x 24" x 7" (L x W x H)], Bio-Matt™ filter fabric internal to the unit, and geotextile fabric covering the unit, placed within a trench/bed of INDOT Spec. 23 sand and installed in a trench, single lateral bed, subsurface bed, above grade bed or an elevated sand mound SAF.
CommentsSEE STANDARD FOR ALL CONDITIONS: design and installation must comply with the Eljen GSF® Geotextile Sand Filter Indiana Design and Installation Manual, April 2020.
Link to Approval Letter & StandardsApproval Letter
Standards
Eljen GSF Indiana Design and Installation Manual, April 2020

Francesville Drainage Tile Corp.
P.O. Box 368
Francesville, IN 47946-0368

Mr. Christopher S. Overmyer

Technology:Gravelless Pipe Technology
Status:Conditional approval
Date:6/27/2002
Description:10" corrugated polyethylene plastic pipe with 3/8" diameter holes located 120 degrees from the top centerline and wrapped with Cariff non-woven polyester geotextile fabric.
CommentsSEE APPROVAL LETTER FOR ALL CONDITIONS: install in gravity trenches only; SAF size: 1 Lf of 10" dia. pipe in great. or eq. to 20" trench corr. to 1 Lf of 3' wide trench.
Link to ApprovalApproval Letter

Haviland Drainage Products Company
P.O. Box 97, 100 West Main Street
Haviland, OH 45851

Mr. Douglas A. Wenninger
Phone: (419) 622-4611

Technology:Graveless Pipe Technology, LPS 56/S
Status:Approved
Date:7/3/2002
Description:LPS 56/S (low profile) gravelless system: 5 corrugated perforated pipes, each with outside diameter of 7.125 inches in 36 inch wide SAF trenches, with geotextile fabric, in lieu of aggregate.
CommentsSEE APPROVAL LETTER FOR ALL CONDITIONS: install in gravity trenches only; pipe must meet AASHTO M-252 Type SP; no size reduction.
Link to ApprovalApproval Letter

Infiltrator Water Technologies, LLC
4 Business Park Road
P.O. Box 768
Old Saybrook, CT 06475

Mr. David Lentz, P.E.
Phone: (860)577-7000
Email: dlentz@infiltratorsystems.net
Website: https://www.infiltratorwater.com/

Technology:Chamber
Status:Approved
Date:1/6/2006
Description:Approved chamber products: Arc 24; Arc 36; Arc 36LP; BioDiffuser; Standard Bio 3 (22” wide); Quick4 Equalizer 36 (22” wide); Quick4 Standard & Quick4 Standard W; Quick4 Plus Standard; Quick4 Plus Standard Low Profile (LP); Quick4 Plus High Capacity.
CommentsSEE STANDARD FOR ALL CONDITIONS: Subsurface trench system only; H-10 load rating; up to 25% size reduction; reduction may not be combined with size reduction allowed for STUs.
Link to StandardsStandards
Technology:EZFlow by Infiltrator
Status:Approved
Date:1/26/2012
Description:Approved product: EZFlow EZ1203H. Synthetic aggregate product using expanded polystyrene (EPS) aggregate held together in cylindrical bundles with high strength polyethylene netting.
CommentsSEE STANDARD FOR ALL CONDITIONS: subsurface trench systems only; design and installation must comply with EZFlow manual and applicable department rules and standards.
Link to Approval Letter & StandardsApproval Letter
Standards
Technology:EZFlow by Infiltrator in Elevated Sand Mounds
Status:Approved
Date:4/24/2019
Description:Approved product: Synthetic aggregate product using expanded polystyrene (EPS) aggregate held together in cylindrical bundles with high strength polyethylene netting.
CommentsSEE STANDARD FOR ALL CONDITIONS AND APPROVED MODELS: use as a stone aggregate substitute in residential and commercial Elevated Sand Mounds; design and installation must comply with EZFlow manual and applicable department rules and standards.
Link to Approval Letter, Manual & Standards

Approval Letter
Standards

Manual

Technology:Infiltrator ATL System
Status:Approved
Date:8/30/2012
Description:Four inch diameter pipe surrounded by a large diameter synthetic aggregate and a small diameter synthetic aggregate covered with a fine geo-textile fabric installed in a sand bed.
CommentsSEE APPROVAL LETTER AND STANDARDS FOR ALL CONDITIONS: design and installation must comply with ATL manual; designers, installers, and LHD staff must be trained and certified; Infiltrator must notify IDOH of all certified persons and all installations.
Link to Approval Letter, Manual & Standards

Approval letter
Standards

Manual

Memo for Dose Size


Presby Environmental, Inc.
143 Airport Road
Whitefield, NH 03598

Ms. Jeanne Allen
Phone: (800) 473-5298
Fax: (603) 837-9864
Email: info@presbyeco.com
Web site: http://www.presbyenvironmental.com/

Technology:Presby Advanced Enviro-Septic (AES) System
Status:Approved
Date:

8/1/2019

Description:Advanced Enviro-Septic (AES) System: Corrugated, perforated, high density pipe with a Bio-Accelerator© fabric along its bottom which is surrounded by a layer of randomized plastic fibers and a sewn geo-textile fabric installed in a sand bed.
CommentsSEE APPROVAL LETTER AND STANDARDS FOR ALL CONDITIONS: design and installation must comply with Presby manual; designers, installers, and LHD staff must be trained and certified; Presby must notify IDOH of all certified persons and all installations.
Link to Standards
Approval Letter
Manual
Standards

Prinsco, Inc.
1717 16th St. NE
Willmar, MN 56201

Mr. Judd Efinger

Phone: (435)727-9002
Email: judde@prinsco.com
Web site:  https://www.prinsco.com/

Technology:Chamber
Status:Approved
Date:9/22/2023
Description:Approved chamber product: Pro4/36
CommentsSEE STANDARD FOR ALL CONDITIONS: Subsurface trench system only; H-10 load rating; up to 25% size reduction; reduction may not be combined with size reduction allowed for STUs.
Link to Standards

Standards

Manual

Technology:Gravelless Pipe Technology
Status:Approved
Date:6/3/2002
Description:Prinsco GLP Sock Pipe: 8" & 10" corrugated polyethylene plastic pipe with 3/8" or 1/2" diameter holes located 120 degrees from the top centerline and wrapped with GLP non-woven polypropylene geotextile fabric.
CommentsSEE APPROVAL LETTER FOR ALL CONDITIONS: install in gravity trenches only; SAF size: 1 Lf of 10" dia. pipe in great. or eq. to 20" trench corr. to 1 Lf of 3' wide trench; 1 Lf of 8" dia. pipe in great. or eq. to 16" trench corr. to 1 Lf of 2' wide trench.
Link to ApprovalApproval Letter

Pretreatment Devices

Pretreatment devices are typically installed upstream of the septic tank in an onsite system and are evaluated on a case-by-case basis.

Algaewheel, Inc.
1426 West 29th Street, Suite 206
Indianapolis, IN 46208

Mr. Chris Limcaco
Phone: (317) 989-2001
Fax: (317) 829-5902
Email: info@algaewheel.com
Web site: http://www.algaewheel.com/

Technology:BacPac Unit
Status:Conditional approval
Date:3/10/2006
Description:Single pass pretreatment system in which algal colonies provide treatment and filtration.
CommentsSEE APPROVAL LETTER FOR ALL CONDITIONS: max. of 50 units (residential & commercial); pretreatment only; unit must be followed by septic tank and SAF that comply with 410 IAC 6-8.1 or 410 IAC 6-10.
Link to ApprovalApproval Letter